If your home is a Victorian villa in Morningside, a Georgian flat off the New Town, a stone-built cottage in East Lothian or a tenement flat in Marchmont, there is a good chance the wiring has grown in layers over the decades. A few sockets added in the 1980s, a shower spur in the 1990s, a kitchen circuit replaced more recently. Individually, much of that work may be sound. Taken together, though, the underlying installation is often rubber-insulated or lead-sheathed cable that has long passed its useful life, a rewireable fuse box with no residual current protection, and lighting circuits running without an earth.
An inspection report is the sensible first step. If it flags code C1 or C2 issues, or the installation simply predates the current wiring regulations, a full rewire is usually the honest answer rather than another round of patching. It is rarely a surprise: period properties ask a great deal of their services, and the electrics are usually the last thing to be brought up to date.
A full rewire is not a case of pulling new cable through old conduits. In practice it means:
Most of the disruption comes from the first two items. Cables have to go somewhere, and in a solid-walled property there is no cavity to hide them in.
Building stock here throws up challenges you would not meet in a modern estate. External walls are often solid sandstone or whinstone, which means chases have to be cut with care and depth is limited. Internal walls may be lath and plaster, which crumbles readily; cutting in is straightforward, but patching needs a plasterer rather than a tub of filler. Ceilings in older flats can be ornate, and cornicing, ceiling roses and panelling all need protecting or working around.
Tenement flats bring their own quirks. Risers, shared access to roof spaces, and neighbours below and above mean coordination and a bit of diplomacy. If your building is listed, or sits in a conservation area, external alterations, meter boxes and any cabling run on the outside of the building may need listed building consent or planning permission before work starts. It is far cheaper to ask first than to unpick it later.
Expect the property to be a building site for the duration. As a rough guide, a one or two-bedroom flat typically takes two to three weeks, a three-bedroom tenement flat three to four weeks, and a large detached villa with outbuildings six weeks or more. The house will not be without power for all of that, but there will be days when circuits are down and you will want to plan around them.
A few practical points make a real difference:
Costs vary widely with size, access, the amount of making good required, and whether you want extras such as garden supplies, an electric vehicle charger or a heat pump ready supply. Get at least three itemised quotes so you can compare like for like, and be wary of a price that does not mention making good, certification or testing.
On completion you should receive an Electrical Installation Certificate, and any work in Scotland that falls under the building standards system may require a building warrant and completion certificate. Keep the certificate, the test schedules and any photographs of cable routes before the floors went back down. They are gold dust if you sell, remortgage or need to trace a fault years later.
Done properly, a rewire is one of the least glamorous but most valuable jobs you can do to a period home. It makes the house safer, easier to live in, and ready for whatever the next few decades of heating, cooking and charging demand.
April 25, 2019 at 10:46 am
Take in the iconic skyline and visit the neighbourhood hangouts that you've only ever seen on TV. Take in the iconic skyline and visit the neighbourhood.
Want to be notified when we launch a new template or an udpate. Just sign up and we'll send you a notification by email.
Soldman Kell
April 25, 2019 at 10:46 am
Take in the iconic skyline and visit the neighbourhood hangouts that you've only ever seen on TV. Take in the iconic skyline and visit the neighbourhood.